Filter Results By:

Products

Applications

Manufacturers

Showing results: 121 - 135 of 141 items found.

  • Highly Inductive Resistance Meter

    MR 8050 - Schuetz Messtechnik GmbH

    With the MR 8050 resistances highly inductive Resistance Meters windings of transformers, motors and reactors can be measured. (range 100 µΩ with 0.01µΩ resolution up to 6 kΩ). The performance of the test objects can be up to 800 MVA or even more. The magnetic loading of a transformer is performed quickly using a high loading voltage (60V). This is important for time critical measurements (cooling curves). The unloading of the transformers core is very fast, very safe, as the energy is total destroyed in the MR 8050.

  • 11 Function Heavy Duty True RMS Industrial MultiMeter

    Extech EX530 - Extech Instruments Corporation

    Ruggedly designed and waterproof to IP67 standards, the EX530 is ideal for use in the outdoors, on boats, and in any harsh industrial environment. It has a double molded housing and is drop-proof up to six feet with a safety rating of CAT IV 600 Volt and CAT III 1000 Volt. It measures AC/DC voltage and current, resistance, capacitance, electronic and electrical frequency, temperature, 4 to 20 mA, and duty cycle. Additional features include: 0.06% basic accuracy, continuity beeper, diode test (2.8 Volt open circuit voltage), 40000 count resolutions, backlit LCD with barograph, peak hold, min/max, relative mode, data hold and 1000 Volt input protection for all functions. Comes complete with double-molded test leads, type K bead wire temperature probe (-4 to 482 degrees F/-20 to 250 degrees C), magnetic hanging strap, case, and a 9v battery.

  • Micro-Ohmmeters

    IBEKO Power AB

    Contact resistance measurement is one of the most important and common tests during switchgear manufacturing, commissioning and maintenance stages. Besides switchgear testing, the RMO digital micro-ohmmeters are designed for simple, safe and efficient testing of:disconnecting switches,high-current bus bar joints,cable splices,welding joints,and different high-current links in factory and high-induction field environments.All DV Power RMO micro-ohmmeters use Kelvin’s 4-point measurement principle which is the most convenient for very small resistance measurements. The measurements are accurate and in accordance with international standards for AC high-voltage circuit breakers testing (IEEE C37.09 and IEC 62271-100).Starting from 2003, DV Power has been a trend-setter on the market when our first 500 A micro-ohmmeter weighing only 8 kg (RMO500A / CPM500) was released.Currently, DV Power products portfolio includes 16 models, divided into 3 series:13 portable models: RMO-A (6) and RMO-G (7) series.6 handheld models: RMO-H (6) seriesThe instruments generate a user-selectable and ripple-free test current up to 800 A in an automatically regulated test ramp. Test current ramping significantly decreases the influence of the magnetic transients to measurement.

  • Micro-Ohmmeters

    RMO-A Series - IBEKO Power AB

    The RMO-A is a portable micro-ohmmeter designed for contact resistance measurements of switchgear during manufacturing, commissioning and maintenance stages. This micro-ohmmeter is widely used by medium and high-voltage circuit breakers manufacturers. Other typical applications are testing of disconnecting switches, high-current bus bar joints, cable splices, and different high-current links. It accurately measures not only in factory environments but also in high-induction fields and substationsThe RMO-A series contains 6 models, rated from 100 A (RMO100A) to 600 A (RMO600A). The RMO500A (formerly CPM500) is our best seller, with 500 A ripple-free current and weighs only 8 kg.Although placed in a very portable and lightweight metal housing, RMO-A micro-ohmmeters have very high output power capabilities. They can generate 600 A test current continuously for up to 20 s. You can test with current up to 100 A without rest time. High output voltage enables a wider measurement range at the highest test currents, as well as the use of thinner/longer test cables. For testing with 100 A, 20 m test leads can be provided with only 16 mm2 cross-section.RMO-A micro-ohmmeter generates a true DC ripple-free (less than 1 %) current with automatically regulated test ramps. During a test, the RMO-A ramps up with increasing current before measuring and decreasing current after the measurement. This significantly decreases magnetic transients and ensures great accuracy.An additional option is a built-in High Precision module suitable for measurement of very low resistances, ranges from 1 to 30 µΩ, with 0,01 µΩ resolution.These instruments can store up to 500 measurements in internal memory. A built-in thermal printer is available as an option.Our free DV Win software communicates with the RMO-A micro-ohmmeters via USB or RS232 interface. It allows you to run the test remotely from PC, as well as to download test results, analyze and generate fully configurable test reports.

  • Mini Automatic Transformer Observation System

    mini-ATOS - Raytech AG

    The mini-ATOS, is a professional multifunctional power transformer and substation diagnostic system. This compact and intelligent instrument can perform many routine and advanced tests such as Winding Resistance (WR), Dynamic Resistance Measurement (DRM), Turns Ratio (TR), Frequency Response of Stray Losses (FRSL), Magnetic Balance, and other diagnostic parameters. With the built-in fully automatic multiplexer, only a one-time connection is required for nearly all functions, which saves a considerable amount of time. The portable, rugged case is perfect for use anywhere onsite or in a laboratory. It is specially designed for fast and easy measurements with the well-known high precision and quality of all Raytech instruments.

  • High Elongation Extensometers

    Model 3800 - Jinan Testing Equipment IE Corporation

    The main body of this unique extensometer remains stationary during testing, held in position by the adjustable magnetic base included. Only the very light, small traveling heads move as the sample elongates during a test. These attach to the sample with small spring clips. Each head pulls a cord out from the extensometer as the head moves. These models use high precision, low friction potentiometers, and, as a result, have a wide range of factory selectable outputs. The extensometer is driven by an excitation voltage and has output proportional to the input. They can be provided with high level outputs (approximately 2-8 VDC) or ones that mimic strain gaged devices (2-4 mV/V). When set to mimic strain gaged extensometers, the Model 3800 can be used with virtually any signal conditioning electronics designed for strain gaged sensors. The potentiometers employ a hybrid wire wound around conductive plastic, which provides excellent long term stability. The output from the extensometer is readily interfaced with most existing test controllers, and may be directly input to data acquisition systems and chart recorders. Please let us know at the time of order what type of output and connector you require.

  • Scanner Probe

    RFS set - Langer EMV-Technik GmbH

    The RFS set consits of three passive near field probes designed for the use in a measurement scanner during the development of E-field and magnetic field. They are designed for frequency ranges of 30 MHz to 3 GHz. The probe heads of the RFS set allow for close measurements needed to correctly localize interference sources on an electronic assembly. They document the whole image of the device under test`s near field. The scanner probes have a sheath current attenuation and are electrically shielded. They are connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance. The measuring signal can be increased with PA 203 or PA 303 preamplifier. On request RFS, LFS and XFS scanner probes can be produced.

  • GAOTek Three-Channel Leakage Current Tester

    GT00YB00ZV - GAO Tek Inc.

    The GAOTek Three-Channel Leakage Current Tester provides online measurement, monitoring, and recording of three channel AC leakage currents simultaneously by adopting the latest CT and magnetic shielding technology. This instrument provides highly accurate and reliable measurements. Additionally, it can locate insulation faults and repair electrical lines. It is composed of a special alloy and consists of a test monitoring software, current clamp, and communication cable. The instrument can store 3900 sets of data and enables online and real time monitoring, historical data inquiry, read, inquire storage, generation, and printing of a fitting curve. It is widely used in 380/220 power systems. It complies with IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ (600 V), and IEC61326 (EMC standard) safety codes.

  • RF Coaxial Probes & Probe Positioner

    Fairview Microwave Inc.

    Fairview Microwave’s line of coaxial RF probes and RF PCB probe positioner are ideal for use with chip evaluations, signal integrity measurements, coplanar waveguide, substrate characterization, gigabit SERDES and test fixture applications. The RF coaxial probes provide return loss better than 10 dB and a maximum operating frequency of 20 GHz. The probes have a 3.5mm female interface, a pitch of 800 or 1500 micron and they can be cable-mounted. They feature gold-plated contacts and can be used by hand, with or without a probe positioner. Compliant coaxial GSG (or GS) pogo pins allow for a broad range of probing angles. The RF PCB probe positioner can hold coaxial probes, has articulated joints and delivers multi-axis positioner control. This positioner also boasts a magnetic mounting plate with on-off positioner switch.

  • Transformer Ratio Meters

    Handheld Turns Ratio & Winding Resistance Tester TWR-H - Amperis sl

    TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.

  • Ground Grid Tester

    GGT Series - IBEKO Power AB

    The GGT500 ground grid integrity tester is designed for inspection of the substation ground grid. It can also be used as a portable micro-ohmmeter with Both Sides Grounded and Remote Control functionalities. It is intended to inspection the conditions of a grounding system beneath substations, testing of medium- and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links.In the United States when inspecting the quality of the grounding systems beneath a substation, the proper procedure is to inject 300 A DC during a time period of 60 s. This is what the GGT500 will do, and in that time period, the current path and voltage drop are checked. Also acting as a micro-ohmmeter, the GGT500 can test low resistance values by producing high test currents of up to 500 A.The instrument is placed in an unbreakable, plastic case with IP67 protective rating (with closed lid). Although very portable and lightweight, micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents, as well as the use of thinner/longer test cables. GGT500 ground grid integrity tester generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. This significantly decreases magnetic transients and ensures great accuracy.When used for testing in Both Sides Grounded conditions, a special current clamp powered from the ground grid integrity tester is used for measuring a current through groundings. If even a higher safety level is required, the remote control feature enables the operator to perform measurements from a distant location, away from the instrument and test object.

  • Magnetic Hall Sensor

    SystematIC

    On basis of extensive experience in Hall Sensor readout and related intellectual property SystematIC has developed several customer-specific and application-specific Hall IC products.For isolated current sensing at DC and low frequencies the Hall sensing technique is a valuable technique. It allows full integration of the sensor elements (Hall plates) and the readout electronics in standard CMOS technology. SystematIC succeeded in combining the full integration with good accuracy parameters and high bandwidth. With a compact die containing magnetic field sensors and programmable readout amplifiers SystematIC contributed to the customers fully integrated current sensor product.SystematIC did the full integrated circuit development and supported in wafer and final test programming. As a result of cooperation with our customer a current-sensor-IC with low offset, high gain accuracy, low TC's and excellent isolation properties has been released for production.

  • Transformer Turns Ratio Testers

    IBEKO Power AB

    Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.

  • Micro-Ohmmeters

    RMO-G Series - IBEKO Power AB

    The RMO-G is a portable micro-ohmmeter designed for contact resistance measurement of non-inductive test objects and applications with increased safety requirement. It tests medium and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links. Due to its Both Sides Grounded and Remote Control functionalities, the instrument accurately measures even in the most demanding environments, providing additional safety to testing personnel.The RMO800G is the most powerful portable micro-ohmmeter on the market with 800 A output current. RMO200G is our best seller in the USA. A user can choose the appropriate model depending on the output current requirement, from 100 A (RMO100G) to 800 A (RMO800G).We use an unbreakable plastic case with IP67 protective rating (with closed lid) for instruments’ housing. Although very portable and lightweight, RMO-G micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents. Consequently, it enables the usage of thinner/longer test cables. RMO-G generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. During the testing, it increases current before measuring and decreases current after the measurement. This significantly decreases magnetic transients and ensures great accuracy.Special current clamps measure a current through groundings when the instrument tests in Both Sides Grounded conditions. The instrument itself powers these clamps. If even higher safety level is required, the Remote Control feature enables the operator to perform measurements from distant locations.RMO-G instruments can store up to 500 measurements in internal memory. Also, they have a built-in thermal printer and USB flash drive available as an option. An additional option is the built-in High Precision module suitable for measurement of very low resistance, in the range from 1 to 30 µΩ, with 0,01 µΩ resolution.Our free DV Win software communicates with the RMO-G micro-ohmmeters via USB or RS232 interface. It allows a user to run the test remotely from a PC. Also, a user can download test results, analyze and generate fully configurable test reports through the software.

  • Turns Ratio Testers

    TRT Advanced Series - IBEKO Power AB

    TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.

Get Help